Posts Tagged panels

Tiny House Solar

I know many of you have been wanting this post for a while, but it’s finally here: my solar panel system for my tiny house.  I wanted to get the feel for what it is like to live off the grid so I could share more details with you all about what it’s really like.

Tiny House solar panels

So first, the high level details of my system:

  • 2.25 Kw panels – Nine, 250 watt panels
  • Batteries 740 amp/hr total – Eight, 370 amp/hr 6 volt Trojan L16 flooded lead acid
  • Cost for parts about $10,000 (excluding tax and shipping)
  • Off grid, battery bank, plus 5,550 watt backup generator
  • 24 volt system

Specific Parts:

  • (9) Canadian Solar CS-6p 250 Watt Poly Black Frame  (Spec Sheet)
  • (1) Schneider SW 4024 (Spec Sheet)
  • (1) Schneider MPPT 60 Charge Controller (Spec Sheet)
  • (8) Trojan L-16 6v 370 AH Flooded Lead Acid Batteries (Spec Sheet)
  • (1) Schneider System Control Panel (Spec Sheet)
  • (1) Schneider Interconnect Panel (no spec sheet)
  • (1) Midnight Solar MNPV 80AMP Dinrail Breaker (Spec Sheet)
  • (2) Midnight Solar Surge Protection Device AC/DC (no spec sheet)
  • 50 Amp RV power Inlet (Spec Sheet)

Before anything I needed to determine the best placement for the solar panels to make sure it had good solar exposure and didn’t fall into shadows too much.  To do this I used a tool called a “solar path finder” which is a semi reflective dome that you position at the location, then snap a photo.  The photo is then loaded into a program and spits out a whole bunch of calculations.

Solar Path Finder

Solar Path Finder

So once you upload the image into the software and then trace the treeline outline, you enter in your location, date and time.  It then can calculate how much power you’ll produce based on 30 years of weather patterns for your exact location and tree coverage.

My reading with the pathfinder

My reading with the pathfinder

Then it spit out all the calculations:

1

With that in mind I knew what I could expect out of the system I had designed.  It also was a way to verify my assumptions.

Once I verified that the system was going to be well suited to my needs I had to build my panel support racking.  I did this out of pressure treated 4×4’s that were each 10′ long.  These things about about 300 lbs each so I don’t have to worry about wind picking up the panels.  I opted to build them because it was cheaper than some of the turn-key option out there and most of the for purchase ones required me to cement in the ground; I rent my land, so I wanted a mobile solution.  The racking is technically mobile, but not easily so.  If I remember correctly it was about $500 in materials to build this part.

IMG_3049

Next we installed the panels.  This part was pretty quick and the stands worked out perfectly.  The panels are 250 watt Canadian solar panels.  They are wired in groups of three, then paralleled into the system.  To give you a sense of scale, these panels are 3.3 wide and about 4 feet tall.

IMG_3057

Now I know many people want to know why I didn’t mount these on my roof or could they mount them.  You technically can mount on your roof, but honestly the number of panels that you need to practically power your house is too many for the roof.

There is some other major bonuses of being on the ground:

  • Much cooler, roofs are very hot places in the summer and solar panels drop in efficiency when hot
  • I can put my house under deciduous trees, this means in summer I’m in the shade, in winter I get the solar gain
  • Way easier to clean and monitor

Cleaning your panels is pretty important because you loose efficiency as residue (bird poop) builds up.  Also as I learned just a few days ago, when it snows, you need to clear your panels.  Cleaning becomes super simple and a lot safer when you don’t have to climb onto a roof via a ladder.

IMG_3284

Just this week we got a decent snow, 3 inches, which is quite a lot for Charlotte.  The first thing I had to do when I woke up was clear off the panels because with the snow, they made no power.  This was compounded because since it was cold, I needed more heat.  I can’t imagine having to drag the ladder out and try climbing on a icy roof… No Thanks.

IMG_3120

Next I built a cabinet to house all the gear.  I wanted a stand alone space because the batteries are so heavy.  At 118 pound each, plus cabling and other equipment the whole unit is over 1,100 lbs.   The top and bottom sections are divided so that the gasses from the batteries don’t go up into the electrical section and explode.  More on that later.

IMG_3112

The batteries are wired in series parallel.  The batteries are 6 volt each, in series of 4 the create a 24 volt unit, then I have two of these 24 volt units in parallel.  The reason I choose to go 24 volt over a 48 volt (which is more efficient) was because the equipment was a little cheaper, but also it allowed me to select components that I could add more panels and batteries very easily without doing equipment upgrades (just a factor of the abilities of the units I choose).  This way I can add up to 15 panels and a lot more batteries without upgrading the electronics; I can also stack these inverters so if I ever go to a normal sized house, I just add another unit and it just plugs into my current one.

IMG_3114

In this photo going left to right: Din Breaker Panel, Charge Controller, Interconnect w/ control panel, inverter.  In general the power flows in the same manner (but not exactly).

  • Breaker Panel: manages power from solar panels
  • Charge Controller: manages power to batteries etc.
  • Interconnect: a main junction box and breaker, holds control panel interface
  • Inverter: takes power in many forms then outputs to they type of power you need

Once the power goes through the system it outputs to a huge cable that you can see sticking out of the bottom of inverter then goes right.  From there it runs to this:

IMG_3127

This is a 50 amp RV style plug.  The reason I did this was two fold.  City inspectors are less picky when it comes to non-hard wired things.  This setup also lets me roll into any RV campground and hook up seamlessly.

IMG_3092

The plug goes into a 50 amp RV female receptacle.  This is important that you don’t have two male ends to your cord.  This is dubbed by electricians as a “suicide cord” because if you plug in to a power source, you have exposed conductors that are live; accidentally touch them, you complete the circuit and zap!

suicide-cable

You want a female end to your cord so that you reduce the chance of being shocked.  I also turn off my main breaker at the power source when I make this connection, then turn it back on.

SimpleElectricCover

If all these mentions of watts, volts, amps, amp hours etc are making your head spin a little, you may need to go back to the basics.  I have an ebook called Shockingly Simple Electrical For Tiny Houses which guide your through all the basics.  As of now, it doesn’t go too deep into the solar aspects, but the basics of electrical, wiring, power systems and determining your power needs are covered in depth and designed for those who are totally new to the topic.

asdfsd

So once the power passes through the power inlet it goes to the panel.  Near the bottom you can see the backside of the power inlet, it has a large black cord coming out of it, into the box and ties to the lugs.  From there it goes out to the house.

IMG_3122

Back outside now, looking at the cabinet, on the sides of it, you can see the vents.  When you use lead acid (LA) batteries you have some off gassing as the batteries discharge and recharge.  These gasses are volatile and can ignite, possible leading to an explosion.  So to take care of this I installed two vents like this which provide adequate venting.  As mentioned before my battery section is isolated from the electronics section where a spark could occur.

This off gassing is a concern with Lead Acid Batteries, but other battery technologies don’t have this issue.  I choose LA batteries over AGM (absorbent glass mat) because LA’s have more cycles and cost a bit less.  Lithium Ion at this point is cost prohibitive.  My batteries should get about 4000-5000 cycles (11-14 years) before I need to replace them.  I figure in about 5 years battery technology will have progressed so much I’ll change early.  New batteries will cost me about $4,000 of the LA variety.  IMG_3123

Here is my grounding wire for my system.  This is actually one of two, another is located at the panels them selves.  My house is also grounded to this through the cable hook up and to the trailer itself.  A really important note: ground depends on a lot of things, one of which is if you house electrical panels is bonded or not, if you don’t know what that means, read up on it, its very important.

The other component of this system is the generators.  In the winter months I may need to top off my batteries every now and then, basically when its been really cold and very cloudy for a week or more.  I had a Honda EB2000i already which I really like.  It’s very quite and small.  The one downside to the Honda is that it only does 1600 watts and only 120V and I needed more power and 240V.  So I picked up another generator, a 5500 watt 240 volt Generac for $650.

generac

Here is a video that compares the two generators in terms of size, noise, output and price.

So that’s the surface level details of the system, I’m going to be doing something in the future which will be a how to size, choose parts, hook up and all the other details of doing solar for your tiny house, but that is a longer term project, most likely will take about 6 months to pull together in the way I’d like to do it.

Tiny House Wood Panel Walls

I am beginning to move into the inside of my tiny house, to insulate and to put up the pine paneling.  A little bit ago I put up some of the pine paneling on the interior wall for what will become the back of the closet.  I had wanted to get back to the tiny house to keep putting up the walls, but some work pulled me away and then it rained, a lot.

The result was the wood paneling swelled up as it absorbed the moisture in the air.  Before anyone ask, yes I did have the wood sitting out in the space to normalize, but with so much rain and the house not being climate controlled yet, the moisture did its damage.  This also happened before I could seal the panels, so that didn’t help either.

photo

You can see the wood had swelled so much that it tore itself free from the nails and bowed out majorly.

I guess the value of my mistake is to prevent this from happening to others.  I just did a little wall when this happened.  Imagine if this were to happen when someone just finished the entire inside!  So how do I plan to prevent this from happening again?

  1. I’m going to make a concerted effort once I start to not stop until I’m mostly done with the main wall panelings.
  2. I’m going to choose a week where the weather should have a pretty even moisture level in the air
  3. As soon as I get the wall paneling up, I’m going to start sealing it right away.  I’ll be trying Tung Oil
  4. I built a insulated temporary door which has weather stripping on it

The temporary door I built is pretty overbuilt honestly, but I figured if I was going to have a temporary door, I might as well do it right and honestly it only took me an hour.  Now if I was building a tiny house inside or if the weather where I lived was even keeled, then this wouldn’t be an issue.  In the past week here in Charlotte it has been dry-ish and 73 degrees and then three days later we had snow where it was 20 degrees.  Its a nightmare for this type of stuff.

For the door I made a frame that fit inside my door frame and then attached a cheap piece of OSB board.  The 2×4’s were $2.30 each (3) the OSB was $7 (1)  Insulation was about $7 worth from a larger pack I’ll be using for the walls.   So $20.90 for the door total.

Now many of you might be asking why I don’t just put on my regular door right now.  The reason for this temporary door is that I decided to put the floor in near the very end of the build so I don’t scratch it.  Since I decided that, I’m still feeling out what the actual final height of floor will be, I don’t know exactly know how low the door must hang.  The door is made, but I want to put the floor in, add the threshold, then adjust the door height and hang it.

Here is the temporary door I made:

photo 1

photo 2In the above photo you’ll notice that the OSB actually extends beyond the frame, this was intentional.  I push this into the door frame and the extra OSB gives me a lip and something to mount the weather stripping to.

photo 3

 

On the bottom of the temporary door I had the OSB go flush so that when I move it around the brunt of the force is on the 2×4’s and not on the OSB.  This is  because OSB is pretty fragile and it can break down.

photo 4

photo 2(1)

photo 3(1)

photo 4(1)